- Internal dimensions (S x H x D): 1860 x 2010 x 2100 mm
- Door dimensions (S x H): 1400 x 2000 mm
- Maximum floor loading: 30000 N/m² (load/unit area)
Work area temperature:
- Temperature range: -40 °C to +85 °C, intermittent
- Temperature constancy: ± 1 K (temporally)
- Cooling speed: 1 K/min in average, between +85 °C and 0 °C with test specimen mass 250 kg (0.25 Wh/kgK)
- Heat-up speed: 1 K/min in average, between -40 °C and +85 °C with test specimen mass 250 kg (0.25 Wh/kgK)
Work area climate:
- Temperature range: +10 °C to +60 °C
- Temperature constancy: ± 0.5 K (temporally)
- Humidity range: 15 % to 95 % r.H. without specimen
- Humidity constancy: ± 5 % r.H (temporally)
- Dew point temperature range: +6 °C to +49 °C